ABB DCS800编程调试 DriveWindow Light V2.7(DWL 2.7)
- 品牌:ABB
ABB DCS800编程调试 DriveWindow Light V2.7(DWL 2.7) 1. Overview
- Processor: Pentium 133 MHz
1. Run the SETUP.EXE from the root directory of this CD.
- DriveWindow Light contains online help which can started
- Making the monitoring window bigger changes the maximum
简介:
1. Overview
===========
DriveWindow Light is a commissioning and maintaining tool
for ACS140, ACS160, ACS350, ACS400, ACH400, ACS550, ACH550
DCS400 and DCS800 drives. Also following ASC600 and ACS800
applications are supported: standard, spinning control and
pump control. DriveWindow Light is designed to run under the
Microsoft Windows NT4.0 (SP6), Windows 2000, Windows XP or
Windows Vista operating systems on IBM -compatible PCs.
2. System requirements
======================
- Processor: Pentium 133 MHz
- Operating System: Windows NT4.0 SP6, Windows 2000,
Windows XP or Windows Vista
- Display: 1024x768 256 colors
- System Memory (RAM): 64 Mbytes
- Hard Disk Space: 80 Mbytes
3. Installation
===============
1. Run the SETUP.EXE from the root directory of this CD.
2. Follow the instructions given by the Installation
Wizard.
4. Getting Help
===============
- DriveWindow Light contains online help which can started
by pressing 'F1' key or from the 'Help' Menu. Online
Help requires MS InternetExplorer 3.0 or later installed
in the computer.
- User's Guide can be found in PDF-format in the
DriveWindow Light Installation directory.
5. Known Issues
===============
- Making the monitoring window bigger changes the maximum
value of the y-axis.
- Large Horse Power ACH400 drives can not be switched from
reverse to forward without stopping the drive first.
- In offline mode formerly saved monitoring data cannot be
opened if no Parameter Browser is open.
- ACS600 software versions 5.x and higher are supported
- Some early versions of ACS550 don't have proper identification
data. Online connection to these drives can be established
using the Force Online -feature.
- While installing DriveWindow Light on Win 2000, you may encounter
an error "Error 1607: Unable to install InstallShield Scripting
runtime." In this case open windows explorer and right under
desktop there is My Documents folder. Right click on the folder
and select Properties. If the Target location field is empty or
you don't have access to the folder specified there, fill in a
folder that you have access on. Try installation again.
- ACx550 SW versions prior to 202c give an illegal value error with
parameter 1602 while restoring or downloading parameters. This is
because the passcode in parameter 1603 is not set in these cases.
- Parameter compare does not work between different languages
- Drive Statuspanel units are taken from corresponding .ini files.
If e.g. ACS550 needs to show Upm (instead of rpm), open ACS550.ini
file (under .Program FilesDriveWareDriveWindow Light 2).
Change the key "Unit" under section [Speed] to value "Upm".
- Editing of binary parameters is not possible in ACS800 drives
- ACx550 and ACS350 files (*.dwp and *.dwm) made with
DriveWindow Light 2.4 or newer are in unicode format. If they are
to be used with older DriveWindow Light versions they must be
converted to ASCII (with Notepad for example).
- With drives using SAP protocol, the monitor data may be lost in
some cases if the monitor settings are adjusted while the
monitoring is on.
- There may be compatibility problems with early sw versions of
ACS350 drives including FlashDrop feature support.
为了维护公平交易的秩序和你我的共同利益,请买家先详细了解物品描述后再谨慎出价。凡出价后不买者或出价后又讨价还价的一律差评加投诉。
我的方屎
Tel172
邮箱:kissmegml@126.com
如本人QQ或邮件不在线时,欲咨询或购物请致电或短信13990026172,或留下你的、邮箱等方尸我回来后定给你满意回复!
本店主营业务简介:
销售各类PLC编程软件、工控组态软件、触摸屏编程软件、数控系统编程软件、CAM/CAM等各类行业专业软件
销售各类工控组态软件和编程软件的加密狗
销售各类高仿工控组态软件和编程软件(含硬件密钥和加密盘等)
销售各类PLC和触摸屏的编程电缆、PLC锂电池、人机界面等
经销三菱、西门子、欧姆龙、AB、GE、台达PLC、触摸屏
经销研华、华北工控 工控机产品及各类智能板卡、适配器、接口转换器等
工控、数控、理化、分析仪器、PLC、变频器、计算机软硬件系统维修等技术服务支持,承接网络工程、自动控制工程咨询、设计、安装、调试。承接老旧系统和进口设备改造,PLC、电脉冲、线切割、坐标磨床等疑难故障维修服务
提供工控、数控、理化分析仪器、计算机、网络工程、微电子技术专业外语翻译服务
热门设计服务
-
最近销售:0 掌柜:缘舍百货¥150 元
-
最近销售:0 掌柜:锦众百货¥75 元